A Novel Transmission Mechanism for MRI-Compatible Surgery Robot

dc.contributor.advisorTsekos, Nikolaos V.
dc.contributor.committeeMemberBecker, Aaron T.
dc.contributor.committeeMemberChen, Guoning
dc.contributor.committeeMemberShi, Weidong
dc.creatorLiu, Xin 1976-
dc.creator.orcid0000-0001-9104-9456
dc.date.accessioned2018-03-12T18:01:45Z
dc.date.available2018-03-12T18:01:45Z
dc.date.createdDecember 2017
dc.date.issued2017-12
dc.date.submittedDecember 2017
dc.date.updated2018-03-12T18:01:45Z
dc.description.abstractMinimally invasive surgery (MIS) techniques provide reduced patient discomfort, faster healing time, decreased risk of complications, and better overall patient outcomes. Medical imaging guidance is particularly crucial for MIS in which the procedure is performed through small openings in the body which resulting in limited sensory information available to surgeon compared with the open approach. Magnetic Resonance Imaging (MRI) is an intrinsically three-dimensional (3D) modality which offers high contrast and spatial resolution and a plethora of soft-tissue contrast mechanisms for assessment of anatomical morphology and function. These benefit , in addition to the fact that it does not require ionizing radiation, makes it a desirable methodology for image-guided interventions (IGI). An impediment to those advancements, however, is the limited access to patients, especially to the high-fi eld cylindrical magnetic resonance (MR) scanners. To address the limited accessibility and facilitate real-time guidance of interventions, remotely actuated and controlled MRI-compatible manipulators have been introduced. The MRI compatible interventional systems require appropriate forms of actuation. The commonly used electromagnetic actuators by many robotic system, like surgical robots, are, in general, not compatible with the MRI environment owing to their magnetically susceptible materials and electromagnetic components which are MR unsafe. In this work, we propose a novel transmission mechanism, herein referred to as Solid-Media Transmission (SMT), to transmit force from MR unsafe components located outside of the MR environment to the end effectors which are MR safe or MR conditional. We focus on the design, fabrication and control of a SMT-based actuator and an integrated robotic system that are aimed to perform the task of a surgical tool or needle placement. Experimental studies have demonstrated the feasibility and characteristics of the SMT and SMT-enabled devices for MRI guided intervention.
dc.description.departmentComputer Science, Department of
dc.format.digitalOriginborn digital
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/10657/2856
dc.language.isoeng
dc.rightsThe author of this work is the copyright owner. UH Libraries and the Texas Digital Library have their permission to store and provide access to this work. Further transmission, reproduction, or presentation of this work is prohibited except with permission of the author(s).
dc.subjectActuators
dc.subjectMechanical power transmission
dc.subjectSolid media transmission
dc.subjectRemote actuation
dc.subjectMagnetic resonance imaging
dc.titleA Novel Transmission Mechanism for MRI-Compatible Surgery Robot
dc.type.dcmiText
dc.type.genreThesis
local.embargo.lift2019-12-01
local.embargo.terms2019-12-01
thesis.degree.collegeCollege of Natural Sciences and Mathematics
thesis.degree.departmentComputer Science, Department of
thesis.degree.disciplineComputer Science
thesis.degree.grantorUniversity of Houston
thesis.degree.levelDoctoral
thesis.degree.nameDoctor of Philosophy

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
LIU-DISSERTATION-2017.pdf
Size:
3.21 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 2 of 2
No Thumbnail Available
Name:
PROQUEST_LICENSE.txt
Size:
4.42 KB
Format:
Plain Text
Description:
No Thumbnail Available
Name:
LICENSE.txt
Size:
1.81 KB
Format:
Plain Text
Description: