Objective Measurement of Spectacle Wear Time with a Temperature Sensor Data Logger

dc.contributor.advisorAnderson, Heather A.
dc.contributor.committeeMemberMarsack, Jason D.
dc.contributor.committeeMemberDas, Vallabh E.
dc.creatorLentsch, Matthew
dc.date.accessioned2019-09-14T01:51:30Z
dc.date.available2019-09-14T01:51:30Z
dc.date.createdMay 2017
dc.date.issued2017-05
dc.date.submittedMay 2017
dc.date.updated2019-09-14T01:51:30Z
dc.description.abstractPurpose: Many practitioners and researchers desire to objectively quantify spectacle wear time. The purpose of this study was to evaluate the Smartbutton Data Logger Temperature Recorder for monitoring spectacle wear. Methods: Fifty adults (32 female, 18 male) wore a thermosensor on their spectacles for 2 weeks for each of 2 mount types while keeping wear diaries. Temperatures during reported spectacle wear (ON) were compared to temperatures during non-wear (OFF). The success of two methods to approximate wear time was evaluated by percent error with respect to subject reported wear time. The first filtered temperatures, defining wear time from temperature ranges determined from group or individual mean temperatures calculated during subject-reported ON times. The second utilized examiners interpreting temperature versus time plots to identify spectacle wear. Results: Group mean ON (31.8 ± 0.6 ⁰C) and OFF (24.7 ± 1.5 ⁰C) temperatures differed significantly (p<0.001), female ON temperatures averaged 1⁰C higher than males (p=0.04), and there was no significant difference in temperature between mounts (p=0.18) by repeated measures ANOVA. Median percent error and first and third quartiles (Q1, Q3) of each approximation technique was: group mean filtering = 8% (Q1 3%, Q3 18%), individual mean filtering = 7% (Q1 4%, Q3 19%), examiner 1 = 6% (Q1 2%, Q3 14%), examiner 2 = 7% (Q1 3%, Q3 12%). Evaluation of the most detailed diaries (8 subjects) revealed that brief wear intervals and leaving spectacles in a warm, parked car resulted in higher percent error in approximating wear time. Conclusions: The SmartButton is a promising device to monitor spectacle compliance in patients with all approximation methods evaluated providing less than 10% median percent error in wear time.
dc.description.departmentOptometry, College of
dc.format.digitalOriginborn digital
dc.format.mimetypeapplication/pdf
dc.identifier.urihttps://hdl.handle.net/10657/4594
dc.language.isoeng
dc.rightsThe author of this work is the copyright owner. UH Libraries and the Texas Digital Library have their permission to store and provide access to this work. Further transmission, reproduction, or presentation of this work is prohibited except with permission of the author(s).
dc.subjectSpectacle Compliance
dc.subjectDose Monitoring
dc.subjectAmblyopia
dc.titleObjective Measurement of Spectacle Wear Time with a Temperature Sensor Data Logger
dc.type.dcmiText
dc.type.genreThesis
thesis.degree.collegeCollege of Optometry
thesis.degree.departmentOptometry, College of
thesis.degree.disciplinePhysiological Optics and Vision Science
thesis.degree.grantorUniversity of Houston
thesis.degree.levelMasters
thesis.degree.nameMaster of Science

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LENTSCH-THESIS-2017.pdf
Size:
1.35 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
LICENSE.txt
Size:
1.82 KB
Format:
Plain Text
Description: