Novel Core Technologies and Systems for Magnetic Resonance Compatible Robotics

dc.contributor.advisorOgmen, Haluk
dc.contributor.advisorTsekos, Nikolaos V.
dc.contributor.committeeMemberContreras-Vidal, Jose L.
dc.contributor.committeeMemberChen, Yuhua
dc.contributor.committeeMemberStafford, R. Jason
dc.creatorVon Sternberg, Nicholas Craig 1986-
dc.date.accessioned2019-06-24T20:15:53Z
dc.date.available2019-06-24T20:15:53Z
dc.date.createdDecember 2013
dc.date.issued2013-12
dc.date.submittedDecember 2013
dc.date.updated2019-06-24T20:15:53Z
dc.description.abstractThis dissertation presents design and validation of several systems and technologies for magnetic resonance imaging (MRI) compatible positioning. The research began as the development of an MRI compatible actuated phantom, which required precise motion through remote actuation. The phantom, which operates from 18 remotely actuated stepper motors, provided motion inside the MRI scanner with submilimeter accuracy and minimal zipper artifacts induced to the images. The motion requirements lead of the phantom project led to the development of a closed-loop motor controller which enabled such accuracy. Maximum absolute error of the tracking a sigmoid function was 0.012 rad, four times the precision of the motor itself. Through the process of developing the actuated phantom, ideas for a flexible, intrinsically MRI compatible method of force transmission were transformed into the Solid Media Flexible Transmission (SMFT) technology presented which can provide force transmission to an end effector up to 4 meters away from the remote actuator without the use of electrically conductive or magnetically susceptible materials. A tool positioning robot was built to demonstrate the technology and SNR reduction of as little as 5% was achieved by filtering the motor drive signals. The methods and experiments provided within demonstrate that traditional electromagnetic motors can be used inside the MRI room with better kinematic results than pneumatic or hydraulic systems and higher force output than piezoelectric motors with the use of the novel SMFT force transmission method.
dc.description.departmentElectrical and Computer Engineering, Department of
dc.format.digitalOriginborn digital
dc.format.mimetypeapplication/pdf
dc.identifier.urihttps://hdl.handle.net/10657/4097
dc.language.isoeng
dc.rightsThe author of this work is the copyright owner. UH Libraries and the Texas Digital Library have their permission to store and provide access to this work. Further transmission, reproduction, or presentation of this work is prohibited except with permission of the author(s).
dc.subjectMRI-compatible robotics
dc.subjectMR Compatible Actuation
dc.subjectSolid Media Flexible Transmission
dc.subjectRobotic Surgery
dc.subjectMagnetic resonance imaging
dc.titleNovel Core Technologies and Systems for Magnetic Resonance Compatible Robotics
dc.type.dcmiText
dc.type.genreThesis
thesis.degree.collegeCullen College of Engineering
thesis.degree.departmentElectrical and Computer Engineering, Department of
thesis.degree.disciplineRobotics
thesis.degree.grantorUniversity of Houston
thesis.degree.levelDoctoral
thesis.degree.nameDoctor of Philosophy

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
VONSTERNBERG-DISSERTATION-2013.pdf
Size:
7.12 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
LICENSE.txt
Size:
1.85 KB
Format:
Plain Text
Description: