Show simple item record

dc.contributorContreras-Vidal, Jose Luis
dc.contributor.authorAkinwande, Samuel
dc.contributor.authorEguren, David
dc.contributor.authorKilicarslan, Atilla
dc.contributor.authorGorges, Jeff
dc.date.accessioned2018-02-27T15:51:49Z
dc.date.available2018-02-27T15:51:49Z
dc.date.issued2017
dc.identifier.urihttp://hdl.handle.net/10657/2491
dc.description.abstractBackground. There are 300,000+ children in the US living with ambulatory disorders. Many of them rely on wheelchairs, which cause health complications due to their sedentary nature. The UH-BMI lab is developing a powered pediatric exoskeleton to reduce wheelchair use in these children. Strain gauges and an encoder were to instrument the joints of the exoskeleton for impedance control. Conclusions. The instrumentation was successful and torques of up to 100Nm can be properly sampled and processed. The samples are obtained at a high frequency to prevent aliasing. The tests provided an adequate model of the joints of the exoskeleton. The data obtained from this project would improve the safety of the exoskeleton.
dc.language.isoen_US
dc.titleJoint Torque Instrumentation in a Pediatric Exoskeleton
dc.typePoster
dc.description.departmentElectrical and Computer Engineering
dc.description.departmentHonors College


Files in this item