Effect of Rapid Alternating Binocular Flicker on Vergence and Stereopsis

dc.contributor.advisorStevenson, Scott B.
dc.contributor.committeeMemberManny, Ruth E.
dc.contributor.committeeMemberCoates, Daniel R.
dc.creatorRamakrishnan, Bhavatharini
dc.date.accessioned2024-01-20T22:05:22Z
dc.date.createdAugust 2023
dc.date.issued2023-08
dc.date.updated2024-01-20T22:05:23Z
dc.description.abstractPurpose: Rapid, alternating occlusion therapy is one of several binocular treatment options for amblyopia. Recent studies suggest it may improve stereoacuity and letter acuity in some amblyopic subjects. Little is known about its impacts on binocular functions like stereopsis and vergence. Here we examine the effect of alternating (out-of-phase) flicker and in phase flicker of different frequencies on stereopsis and vergence eye movements. Methodology: Stereoscopic disparity thresholds were measured using a 30 trial, 1 up 2 down staircase beginning at 10 arc minutes disparity. Five staircases were obtained from each of five healthy adult subjects for all combinations of contrast (100%, 50%, 25%) and flicker (2, 4, 8, 16 and 32Hz, in-phase and out of phase binocular flicker, and no flicker). The stimulus was a spatially filtered noise pattern (1 cpd, 1 octave bandwidth), presented for one second. Vergence eye movements were measured using a binocular dual Purkinje image eye tracker. The vergence target was a 30-degree diameter filtered noise pattern of spatial frequency either 0.25 or 2 c/deg with a bandwidth of 1 octave. Stimulus contrast ranged from 3% to 100%. The trials were 2 seconds long. Results: Flicker elevated stereoscopic thresholds in most subjects. The flicker did not abolish stereopsis, however: subjects were able to detect a few arc minutes of disparity at all but the lowest frequencies alternating phase flicker. Lower frequencies of flicker impaired but did not abolish stereoscopic thresholds in most subjects. Vergence responses did not show any difference at higher contrast stimuli for all the flicker frequencies. At lower contrasts, latency, velocity, and final amplitude accuracy were lower for lower frequency compared to high frequency flicker. Conclusion: When it comes to stereopsis, results show that thresholds are elevated by both alternate and in phase flicker but are mildly impacted only at the lowest temporal frequencies of 2 and 4Hz. The results of vergence measures show that there are minor differences in vergence responses between out of phase and in phase flicker and the vergence responses showed a trend of decrease in vergence performance compared to vergence responses with in-phase flicker.
dc.description.departmentOptometry, College of
dc.format.digitalOriginborn digital
dc.format.mimetypeapplication/pdf
dc.identifier.urihttps://hdl.handle.net/10657/15989
dc.language.isoeng
dc.rightsThe author of this work is the copyright owner. UH Libraries and the Texas Digital Library have their permission to store and provide access to this work. Further transmission, reproduction, or presentation of this work is prohibited except with permission of the author(s).
dc.subjectStereopsis
dc.subjectocular convergence
dc.subjectocular divergence
dc.subjectalternating flicker
dc.titleEffect of Rapid Alternating Binocular Flicker on Vergence and Stereopsis
dc.type.dcmitext
dc.type.genreThesis
dcterms.accessRightsThe full text of this item is not available at this time because the student has placed this item under an embargo for a period of time. The Libraries are not authorized to provide a copy of this work during the embargo period.
local.embargo.lift2025-08-01
local.embargo.terms2025-08-01
thesis.degree.collegeCollege of Optometry
thesis.degree.departmentOptometry, College of
thesis.degree.disciplinePhysiological Optics and Vision Science
thesis.degree.grantorUniversity of Houston
thesis.degree.levelMasters
thesis.degree.nameMaster of Science

Files

License bundle

Now showing 1 - 2 of 2
No Thumbnail Available
Name:
PROQUEST_LICENSE.txt
Size:
4.44 KB
Format:
Plain Text
Description:
No Thumbnail Available
Name:
LICENSE.txt
Size:
1.83 KB
Format:
Plain Text
Description: