• Login
    View Item 
    •   Repository Home
    • Electronic Theses and Dissertations
    • Published ETD Collection
    • View Item
    •   Repository Home
    • Electronic Theses and Dissertations
    • Published ETD Collection
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Manipulating Cells with a Dynamically Reconfigurable Electro-magnetic Coil

    Thumbnail
    View/Open
    JIANG-DISSERTATION-2015.pdf (5.645Mb)
    Date
    2015-05
    Author
    Jiang, Ruoli
    Metadata
    Show full item record
    Abstract
    Current cancer screening techniques are often labor-intensive, require high initial costs, and are difficult to apply to cytology samples because of their heterogeneous nature. To address these issues, we are participating in a project to develop a low-cost chip for cell enrichment. The proposed system uses water-based bio-compatible ferrofluids as a uniform magnetic environment that surrounds the non-magnetic (cancer) cells within a set of microfluidic channels and reservoirs. The novelty of our approach is that we apply an external magnetic field generated by a dynamically-reconfigurable electromagnetic coil. The magnetic field will push away the non-magnetic objects (including cancer cells) so that they can be potentially trapped, manipulated, and directed towards a specific location. In this research, we developed the reconfigurable electromagnetic coil with the help of a mathematical model of the motion of non-magnetic particles in ferrofluids induced by (changing) magnetic fields. This model was used to compute the magnetic fields required for effective particle manipulation. Test results of an actual microfluidic device equipped with our electromagnetic coil are presented.A microfluidic device with electromagnetic wire-mesh coil has been developed. Bench experiments on single wire and parallel wires configurations have achieved non-magnetic trapping and manipulation with speed around 50 μm/s. Experiments with the figure-eight coil configuration differed from the simulations, but a ‘sandwich’ type coil could improve on these results.
    URI
    http://hdl.handle.net/10657/1972
    Collections
    • Published ETD Collection

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    TDL
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsDepartmentsTitlesSubjectsThis CollectionBy Issue DateAuthorsDepartmentsTitlesSubjects

    My Account

    Login

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    TDL
    Theme by 
    Atmire NV